PVC windows for your home long-term, is an investment using the cost-effective and energy efficient. A service life exceeding 50 years should be carefully considered when selecting those which window system. Therefore, specific requests and requirements involving the key issues related to the window that will help you choose the most suitable products for which we have prepared an information sheet. Please do not hesitate to you at any time if you need any help to get in touch with one of our nearest specialist. PASSIVE HOUSE Passive House 2009-2019; Loss of energy and carbon emissions to 0 (zero), close in clean air hosts (ventilation quality) is called resistant and strong house. In other words, structures that allow us to obtain high quality air and heat with very low energy. The way of gathering under one roof these items is through good design. Building from the building when designing solar lights, thermal bridges, thermal insulation, ventilation ways to make healthy, care must be taken for efficient use of interior heat sources. For example, if too large or small interior heat sources, they lead to unnecessary consumption if not taken in the proper place. While the outside temperature is -12ºC to 21ºC in areas near heat sources within the building’s walls and heat in areas such as glass surface, in contrast to less insulated building, which is expected to be 9ºC to 17ºC when the Passive House to fulfill them all. Good Passive House to expected = 15 kWh / m2 / year is needed with temperature and wherein the window = 0.8 W / m2 / K is expected to perform similarly. According to research carried out in Frankfurt annual 290kwh / m² energy spent building after the necessary work in the same conditions 17kwh / m² began to energy expenditure. First Passive House was built in 1991, in 2009 it is estimated that the building can be described as more than 13,000 Passive House in Germany. In fact, all public and social buildings in Frankfurt has the obligation to build on these qualities. In insulated houses in Turkey, according to the Passive House 20 times more energy is wasted. In our country, it is given the weight of the years 2000s to study this kind of way and significant progress was made in terms of thermal insulation according to the data of the 1980s. TS 825 Thermal insulation in buildings and revised Standards were introduced in 2008 and then published in the Energy Efficiency Act of 2007, in this context, building insulation sheet thickness reached 25 cm. Uwe value of the window is between 2.4-2.8 according to the criteria in 2000 to 2.4 this value was taken in 2008. 5 December 2008, Energy Performance Regulations have been published, and accordingly, no longer mandatory to keep energy identity card for each new building and energy needs of the building, lost, etc. such information is made difficult to be clearly stated in this identity (such as CE requirement results in structural performance label). Since 2007, Europe has begun implementation of the energy certificate for buildings in some countries. annual total energy used in Turkey 105 million TOE (Tons of Oil Equivalent) $ 65 billion money ’is. This is 74% of the needs are imported. According to the 2008 data, we do $ 48 billion energy imports. If this energy is an important part of the 26.4 million TPI’s thought to be used in buildings can talk about the energy consumption of buildings of up to $ 13.6 billion. Even assuming that only 50% of lost years, 6,8mily are $ = 12 Billion is spent in vain. All of these reasons prior to the thermal insulation of $ 400 million per year in 2008, while spending $ 200 billion has been spent. In our country there are 18 million homes. There is no insulation in 15 million homes almost never known that by that 3 million in recent years. While the values of 0,1m³ insulating material consumption per person per year in Europe, some even 1,0m³ 0,7m³. In the previous year in Europe 1 ton of CO2 You nature is less release to need to invest up to 40 € in considering the current building, this value is 150 € for up to increased cases (CO2 emissions of oil etc. are considered equivalent to the use of fuel). Carbon emissions and energy use of the Kyoto Protocol by the planned reduction of 8% in 2008-2012. European Energy Security (ene) in 2020 than in 1990 according to what is planned to be reduced by at least 20%. Today, as an incorrect assessment of triple glass thermal insulation in cold regions are expected to be good. However, heat insulation in hot regions is so important. Thermal insulation reduces energy costs originating from a building with good air conditioning. In recent years, faced with the Passive House concept, especially in Western and Central Europe. These houses may be called passive house, the window to the wall and roof insulation materials used for almost all the details well to heat and heat without the need for any human breath can be considered as a heater structures. It is considered the highest level of course be reached. We thought that the purpose of what we are able to get close enough. Passive houses are longer uses three glass as standard. Conventional new buildings or modified buildings can benefit from the advantages offered by the system and triple-glazed owners to take when deciding which products should consider it. Triple glazing system stands out with the following features:
Saving Energy and Money with three glass System Old single-glazed windows and cold transmission speeds and lead to higher heating costs. thermal insulation of modern windows is much better now compared to a few years. By comparison: In the early eighties the single glazed window approx. 5-6 W / m2k’lık has an average heat transfer coefficient. From the perspective of today, energy saving windows 1.5 W / m2K on Uwe not required to have a value. Future ≤0.95 W / m2k’lık Uwe values are considered already. This amount of energy corresponds to a saving of over five times. This means that the heating costs and energy consumption is the only way effectively reduced. Today, the extra cost is a minimum of three glass and through higher energy efficiency is quickly pays for itself. Old windows with insulating glazing (U-value of 2.8 W / m2K), 1:48 x 1.23 m standard window. The basis of the calculation of heating costs: fuel costs 0.70 Euro / Litre, window area of 50 m2. Apart from financial benefits, there are also advantages for the occupants. Three glass modern apartments and houses also offers enhanced comfort and a cozy life is noticeably. When you change your window that financial savings can be calculated with energy saving calculator. Three Cain with Advanced Comfort and More Comfortable Life We are familiar with all these shares. We feel a cold draft near the window in the cold season. They’re cold areas around windows and open extra heating. Wellbeing sensation is not only a function of the ambient temperature and air flow is also affected in the floor or wall surfaces, and also the temperature of the window. the hotter the surface of the colder surface of the larger temperature difference between the individual surfaces causes heat absorption. People perceive it as cold skin temperature and will impact on our sense of the situation. and airflow three glass has a significant effect on both the surface temperature. Three glass-Thermal Comfort Lower heat losses that provide us comfort is due to the high thermal insulation value three glass. The gaps between the glass sheets triple-glazed windows are filled with rare gas having low thermal conductivity. This means that only very little heat may pass between the outer glass sheet can escape. Thus it heats the inner layer is relatively high. Double glazing and an outside temperature of 10 degrees centigrade to 20 degrees centigrade compared with three in a room temperature CAs in Rosenheim Testing Institute (Pairs) heat in a research conducted has been identified as different almost 9 degrees. three glass while the double glazed inner surface temperature was 9.5 degrees with an inner surface temperature of 17.7 degrees. The small difference between indoor surface temperature and room temperature and other surface temperature as a result of a feeling of well-being has increased significantly. There is no air flow, and a "lake of cold air" brought the end of the tremor occurred not in the window edge. Three glasses of those planning new construction or renovations to think seriously about and do not want to compare the price would be right. For Windows-Value Calculation
The heat transfer coefficient is related to the entire Uwe window. This value also includes a U-value of the glass and frame NF. Uwe also the overall value of the linear heat transfer coefficient (g = glass) and is influenced by the window size. Of Window Glass U-value: Ug Ug value of the intermediate space between the glass sheets gas filling type, and layer number is a function of the distance between layers. The window frame U-value: Uf Uf value of frame-panel combination is determined by calculation or measurement. A sectional area profile for the calculation of Uw values. Linear heat transfer coefficient Øg Øg value of the glass edge seal is a function of the materials used in insulated glass spacer before everything. Worst thermal features standard material is aluminum. Search with improved thermal insulation parts "warm edge" is called spacers. These spacers are made from stainless steel or plastic. Frame profile of the insulated glass edge seal using a cloth edged in larger Y-value is further improved. Ø Examples of values:
U-value window: Uw Windows and window doors to the heat transfer coefficient of 1.23 x 1:48 m Uwe usually calculated on the standard window size. Important: Dimensions of smaller-value deteriorates; larger windows give better values. This is because the framework materials of values obtained when the glass is better, and therefore can give a better thermal insulation values of a larger window area. Calculation of Uw values The following formula is used to determine the heat transfer coefficient:
Ug = heat transfer coefficient of glass Sound insulation Noise pollution could significantly harm the living comfort is often a cause of stress and frustration. Acoustic windows offer a quick solution and noise pollution
They offer solutions. Quality acoustic windows Why is it Important? According to the situation of the windows in the new building and conversion projects, it is extremely important to neglect the good sound insulation. The human ear is one of our most sensitive sense organ. from 16 to 16,000 Hz and having a pitch perception. Even when we sleep in the human sense of hearing it is extremely active and sensitive. The maximum noise level exposure to an appropriate depth is 25 dB, according to scientific findings. However, today is finding this level can not be achieved without a proper sound insulation and a large percentage is getting more unpleasant and disturbing noise sources from outside of the general population. The negative effects of exposure to environmental noise is often the subject of public discussion. Challenge is presented below an overview of the level of noise from different living conditions and construction status.
The volume of living space
Bedroom 20 – 25 dB(A) You can clearly achieve effective protection against noise pollution with görüyoruzwinsa acoustic window that we compare these two tables is a good acoustic protection is absolutely indispensable today. Winsa window systems comply with protection class noise from below. Sliding Windows - Stylish Way of connecting inside to outside Sliding windows provide external environment is an excellent way to move inside and also spacious window areas. Nature and gardens and even in the worst winter weather poses a part of everyday life. In good weather window can be opened easily. elements from ceiling to floor even filtered almost sideways thanks to the technology driving Winsa. At a glance, if the sliding window to get the Wi s WILL
Sliding Window Opening Tactics Winsa sliding windows open with different technical solutions available. Each slide system offers certain advantages to meet individual demands and needs. There are three different Winsa sliding window system options. Panorama HS 76 Hebeschiebe Technology with Sliding Windows Lifting sliding windows and sliding door technology on the other hand large areas while benefiting from the comfort of a flat threshold allows you to call. Up to four panels can be moved effortlessly view and a walk-in element plane window to create an exceptional panoramic view. Extremely good thermal insulation values increase energy efficiency and make it easier to use the remote control motorized sliding windows versions. Lifting and sliding doors can obtain more detailed information on our product page. Parallel Sliding Windows Fully automatic and semi-automatic parallel sliding windows are available as an option. Excellent waterproofing and exceptional thermal and acoustic insulation, as well as ease of use stand out. With this system the additional measures may be applied at any time, improved protection against theft. Tilt / shift systems Dorado Gold Dorado, Sapphire and Carina can be applied to our system. Folding Sliding Windows System This drive system using the front view window can be opened completely or to prevent outside access without fixed panels or moldings. For this purpose, it is thrust aside as accordion folding doors individual elements. Private holding plates of the individual panels can be opened and folding door makes it possible to be any partially open position. Folding systems Dorado Gold, Sapphire and Dorado can be applied to our system.
TPE Conta------- RAL Quality Mark describes the letters and the seal of the RAL Institute. RAL quality seal name and Germany and is recognized as a symbol of superior quality products and services worldwide. RAL name in 1925 in the German private sector, and the German government "Reichs-Ausschuss for Lieferbedingung that" (RAL) or State Delivery Terms has since set up the Commission. The common goal technique has been to clarify the delivery terms and standardization. The quality requirements have been identified for this purpose and its follow-up required respectively. the Institute has created independently and exclusive responsibility rules and regulations. Target never, not only to the delivery process of rationalization, primarily has been to ensure quality standards. in this context, the protection of the quality assurance approach, the promotion of integrity in business through honesty and clarity in labeling and consumer interests of goods and services given the importance of a reliable marking. RAL quality assurance with the name of the increasing concentration then State Delivery Terms and Quality assurance Commission (Reichs-Ausschuss for Lieferbedingung und Gütesicherung) has been expanded to. After the war, the German RAL standards committee of Deutsche Normen Ausschuss (DNA) is connected. RAL directed by the president without legal status of DNA, but have worked in an independent and autonomous way. But then, gradually it decided in a short time with increased duties and responsibilities of legal status and this has led to the establishment of the seventies in RAL e.v.’n; Since 1980 the institute "RAL Deutsches Institut für Gütesicherung under Kennzeichnung e. V "is the name. RAL is responsible for the RAL Quality Marks, RAL Agreements, Registration of RAL RAL test specifications and includes the Geographical Origin Marking rations. In addition, since 2008, RAL colors, RAL the Environmental Label and European Environmental Label has been part of the RAL RAL e.v.’n GmbH, a 100% subsidiary of responsibility. www.ral.de on the website and in our RAL Installation Guide Information Pages You can find more detailed information. RAL Installation High thermal and low air permeability since the origin of the window, the window during the installation of the connection to the building structure has also to be made air tight as possible. RAL Gütegemeinschaft Fenster und Türen E. V. (Quality Assurance Association for windows and doors) is bent in detail on this matter and the production of windows and external doors in 1994 and has published instructions on installation (Leitfaden zur Planung und Ausführung der Montage von Fenster und Haustüre that). RAL windows and exterior doors of this directive is to describe the application of standardized connection to the building structure and professional quality association Gütegemeinschaft RAL test institute in Rosenheim has been prepared in cooperation with the pairs. This directive applies to all sectors are considered as a reference survey. RAL Proper Window Installation Guidelines - Definition of Terms Incorrectly describes the installation of windows and doors airtight ’RAL installation "is used herein. To be sure "RAL installation" There is no such thing and that the term is not protected in this way. Installation of windows and doors should always be carried out in accordance with the RAL installation guidelines, because the guidelines are based on the main content of DIN recognized technology rules. RAL Quality Mark for Windows + Mounting An additional duties quality label is derived from a quality standard guidelines and is now protected by the RAL Quality Mark + Windows installation. This mark of quality windows and doors and involves the installation of these quality standards. Since June 2010 just mounted the engaged companies can apply for a RAL Quality Mark. Companies with the quality mark comply with the specific standards laid down in the directive. These companies employ only trained installers, business is properly applied documents and ift Rosenheim as neutral institutions are also inspected and approved as a volunteer. The RAL Quality Mark are required to apply to companies that want to have the following requirements:
In this way the RAL Quality Mark are offered primarily to end users with reliable quality standards and also to guarantee a consistent quality material from production to installation. RAL Institute and Union Front Window + You can find more information at the website. Ventilation of the window and Habitats In particular, the thermal insulation of advanced ventilation of living space in new buildings is of great importance. on the other hand, while getting a pleasant climate with a living room atmosphere and ventilate right can prevent damage to the building. Proper ventilation is extremely important for the following reasons:
Ventilation window Do not change the air in the room through the window ventilation, humidity regulation and reduce the risk of mold growth is the easiest and fastest way. There are three ways of doing this: Curved windows / ventilation especially with today's thermal insulation standards through curved windows is not recommended in winter and wet room. Windows are deposited to ensure that the natural air. This aeration process, particularly over a long period is not recommended. This is because in this case the window sill and jamb of the excessive cooling water and condensate is increased risk of mold growth. Sudden ventilation / window panel opens up to the end for a short time (4 - 10 minutes). This provides a rapid air exchange and energy losses are minimized. Cereda airing / Cereda is the most effective way of airing a room ventilation. For this, the windows and the doors are opened so as to create a draft and that all air 2 - leads to changes in 4 minutes. Ventilation standard DIN 1946-6 Ensuring clean air to the living space and buildings especially in the light of an issue which is becoming increasingly important in modern construction methods and energy efficiency available today. Therefore, ventilation standard DIN 1946-6'n the updated version was published after a long revision process. Target of the ventilation standard focuses on the following key points:
A ventilation in accordance with DIN 1946-6 Preparation of Concept When desired? Energy Savings section 6 of the Regulation envisages the preparation of a ventilation concept for all new buildings in accordance with DIN 1946-6. also in the construction project, it is necessary to create a ventilation concept in case of a new roof insulation more than single-family homes and the replacement of more than one-third of the windows in the apartment or one-third of the roof area. Ventilation concept is always the responsibility of the property owner should outsource this work. D 1946-6'n Basic Element: Through the four ventilation Level 1. ventilation for moisture insulation This level of aeration of the building as a function of the respective levels of thermal insulation to provide adequate venting. The aim is to avoid caused by moisture in the building and also during the absence of residents and reduced the damage caused by moisture load. This ventilation should be ensured at all times and is connected to the user. 2. Reduced ventilation This level of aeration is dependent on the actual user. In this case the minimum hygiene standards and the lack of short-term residents to protect the building (daily operation and so on.) Must be provided during. 3. Normal ventilation Under normal operating conditions of hygiene and health standards of normal ventilation and also define the minimum air exchange rate required for the protection of the building. residents in some cases may include the active participation of normal ventilation window ventilation method. 4. Intensive ventilation Intensive ventilation cooking meals, washing and so on. Why is that aimed at alleviating extreme loads. Building residents can also participate in an effective manner to this level of ventilation by opening windows. Insulation levels and the location of the building is included in the basic calculations related to ventilation level in accordance with DIN 1946-6. In this way, any kind of leak is detected within the building, estimated loads are taken into account on the basis of available floor space and estimated natural air filtration through the use of wind loads. According to the concept, to provide protection against moisture natural ventilation air supply will be required to provide additional ventilation measures are insufficient if the designer responsible for ventilation. In addition, the decisive issue in the new DIN 1946-6 designers provide legal certainty. However, some issues are still omitted condition. For example, the determination of the amount of active ventilation window that can be expected from an employee full-time residents of the building are not possible. Mild winters or spring and suitability to different weather conditions such as general transitional seasons like fall poses a problem. The reason for this is to be required several times a day of a complete air exchange in some weather conditions or severe temperature fluctuations. Ventilation standard DIN 1946-6'y Proper ventilation concept of who should make? A ventilation concept ventilation measures or repairs planning and carrying out or planning of the building and engaged in the modernization can be prepared by any expert. D planning tools for a proper ventilation concept to 1946-6'y can be downloaded from the internet. Ventilation concept is always the responsibility of the property owner should outsource this work. You can find advice on effective air conditioning in the living area and more Info Page ventilation window on our page. Habitat moisture and mold formation in a pleasant room climate is essential for the well-being of feeling at home. Room humidity has a significant impact on the quality of the room climate. a relative humidity of 40% to 65% is generally considered as a healthy and comfortable room climate. Relative humidity is mostly a function of the following factors:
True, the room climate is also extremely important for the protection of the health and living tissue building. Suitable room climate can prevent the formation of mold in wet areas or colder point in the outer wall effectively. Therefore, to prevent the growth of mold, it is necessary to keep an appropriate structural conditions by venting moisture quiet and a good level for the building. Temperature, humidity and mold formation Relations between the amount of moisture in a cubic meter of air varies as a function of temperature. Warm air can absorb more moisture than cold air based. 20 ° C room temperature and a cubic room air at a relative humidity of 60% containing 10 g of water. air in the room of the room temperature falls to 8 ° C will be able to absorb moisture only half of this amount. This means that as the escape of moisture and condensation is 50% of the precipitation mostly colder exterior walls. Therefore increases the risk of mold growth in those areas. The Dew Point Temperature and relative humidity reaches 100% mold Respect Critical thresholds excess moisture starts to condense and form water condensation. Condensation temperature, dew point given that the name of the place. dew point due to a function of the relative humidity of the air temperature varies depending on the respective condition. For example the dew point at a room temperature of 20 ° C with a relative humidity of 50% 9.3 ° C. We now know, we can begin to occur even in a room at 80% moisture mold. This means that in this example the walls of the mold, especially at the corners and niches can begin to form at a surface temperature of 12.6 ° C or below. Edited by venting moisture right, as indicated previously maintained at a favorable level. Venting of habitat due to modern construction standards and the increasing need for energy efficiency in new buildings, more and more attention is given to the subject. For example, providing ventilation standard DIN 1946-6 from a minimum air exchange rate for new buildings or major renovations project for 2009 envisages the preparation of a ventilation concept. Window Replacement - Window Renewal: amend the Savings Building Window New Window provides clear advantages. The most important are:
A great view - a simple and quick exchange window for improved comfort. Window Replacement: Fast, Cost-Effective is the most convenient solution in terms of cost and maintenance replacement windows for efficient construction. often it ignored how easy and immediate change may be a window. A new window can be fitted quickly. the reduction of heating costs for the next year as well as you also protect the environment. PVC windows are particularly effective in this regard and they are class leaders in eco-balances .. 15-20 years ago, replacing old windows installed will allow you azaltabilme over 40% of heat loss. The facade and the roof of the amendment can bring even greater energy savings potential. More comfort - Reduced costs of replacing the window Detached family house is about 8 years to pay for itself and provide more comfort and well-being feeling. The example given here is based on the calculation of the average value of a detached family house with a window area of about 40 square meters (status: October 2010). a heating oil price of EUR 0.70 per liter calculation is based. Values were determined by using a standardized calculation method (excluding errors and omissions). If your investment will pay for itself in fuel prices rise more quickly. Inoutic window systems offer many advantages is perfectly suited to renovations:
You can calculate your windows do you save energy while changing track machine account. Using an overview of the products found in the right window system for your project. We offer individual design options and sophisticated solutions. Window always our experts to assist you in your building and window placement on the new routes will be happy to advise you. Recommendations Regarding the cleaning of PVC windows PVC windows are extremely easy to care for and require minimum maintenance. But again, PVC windows, especially windows need to do to clean them regularly and care. for a long time it will allow you to take advantage of the right operating window.
Regular cleaning is Winsa suggest the following procedure as needed:
Profile, glass and links to Avoid lime and mortar splashes. Solidified mortar residue can clog connections to both the damage and the glass profile. Ventilate rooms several times a day!
Do not use abrasive liquids
Use a mild solution of dishwashing detergent in the regular cleaning of the surface of the frame. Do not use abrasives or solvents. Always use special cleaning agents that can be taken from the window or a window specialist suppliers for stubborn dirt. Outside regular cleaning!
You clean the outside of your windows regularly. Sunlight pollen, can lead to penetration of tar or ferrous particles. After the removal of a buried layer is not easy. Lubricate links!
Always lubricate the movement to ensure ease of connection at least once a year. Tighten the handle!
Always tighten loose window handles. You can find the screws through the bottom of the handle to lift the lid and bring to a vertical position to a horizontal position. Perform maintenance on the wick!
Soft and wicks with a sealing agent twice a year to keep it in working order in the frame, for example. powder, oil or silicon oil with deer (taken from the experts) rub. Damaged gaskets must be replaced. Clean drainage openings!
Check occasionally to ensure water drainage openings in the frame profiles evacuation. Cleaning is important for adequate water drainage. |
||